01 / THE NOTATION
What the fit is
That overlap gives accurate location without guaranteed looseness or a strong press fit. Each assembly falls somewhere between the extremes, so both must be checked.
H7 has its lower deviation at zero and the IT7 width; k6 sits close to nominal with a positive offset and the IT6 width. At 10, 25 and 50 mm the shaft lower deviation is smaller than the hole upper deviation, so the zones overlap.
The loosest assembly uses the largest hole and smallest shaft; the tightest uses the smallest hole and largest shaft. Both are legitimate outcomes, and neither is guaranteed for a particular assembly.
This is a transition fit, not a guaranteed clearance or interference fit, and not a substitute for a torque-joint design. Friction depends on the actual interference, contact length, materials and surface finish.
02 / WHERE IT FITS
Typical uses
H7/k6 is used where a part must be centred and held with little play but assembled or removed with light force: gears, pulleys, handwheels, hubs, flywheels, couplings, locating covers and fixture details.
Combine it with a key, spline, clamp or retainer when torque must be transmitted; do not rely on friction alone without checking the joint. For free sliding, use a clearance fit; to prevent separation under load, use a stronger interference fit or a positive drive.
Bearing suppliers' recommendations take precedence for bearing applications.
03 / WORK IT THROUGH
Limit deviations and worked examples
The table gives limit deviations in micrometres. ES/EI are hole upper/lower deviations; es/ei are shaft upper/lower. The transition extremes are c_max = ES - ei for maximum clearance and i_max = es - EI for maximum interference.
| Nominal mm | Size interval mm | H7 hole ES / EI µm | k6 shaft es / ei µm | H7 hole limits mm | k6 shaft limits mm |
|---|---|---|---|---|---|
| 10 ↗ | over 6 up to 10 | +15 / 0 | +10 / +1 | 10.000–10.015 | 10.001–10.010 |
| 25 ↗ | over 18 up to 30 | +21 / 0 | +15 / +2 | 25.000–25.021 | 25.002–25.015 |
| 50 ↗ | over 30 up to 50 | +25 / 0 | +18 / +2 | 50.000–50.025 | 50.002–50.018 |
Deviations are checked against this site's ISO 286 implementation (dataset ISO 286-1:2010 / ISO 286-2:2010); limit sizes are nominal + deviation / 1000.
At 10 mm: maximum clearance = +15 - (+1) = 14 µm; maximum interference = +10 - 0 = 10 µm.
At 25 mm: maximum clearance = +21 - (+2) = 19 µm; maximum interference = +15 - 0 = 15 µm. The 25 mm limit sizes are an H7 hole from 25.000 to 25.021 mm and a k6 shaft from 25.002 to 25.015 mm. In millimetres, maximum clearance = 25.021 - 25.002 = 0.019 mm and maximum interference = 25.015 - 25.000 = 0.015 mm.
At 50 mm: maximum clearance = +25 - (+2) = 23 µm; maximum interference = +18 - 0 = 18 µm.
At all three sizes the fit can produce either condition. The shaft lower deviation leaves a clearance possibility, while the shaft upper deviation crosses the hole lower limit and produces interference.
Check the 25 mm example in the calculator ↗04 / NEARBY FITS
Comparison with neighbouring fits
H7/h6 is a locational clearance fit that can reach zero clearance but cannot produce interference. H7/js6 is also a transition fit, but its zone is centred on nominal size, so it is less biased toward interference than H7/k6. H7/n6 shifts farther upward and is more strongly interference-biased. H7/p6 is normally a press fit, and H7/s6 is heavier. H7/g6 is a closer running fit with positive clearance, while H8/f7 is wider and H9/d9 is looser. These comparisons are qualitative, and the tabulated limits at the actual size decide. GB/T 1800.1-2020 is listed by the SAMR national standards catalogue as a modified adoption (MOD) of ISO 286-1:2010; GB/T 1800.2 table values have not been compared on this page and are to be verified.
05 / FREQUENT QUESTIONS
A few details worth getting right
What does H7/k6 mean?
It is a hole-basis fit with an H7 hole and a k6 shaft, with the shaft zone overlapping the hole zone.
Is H7/k6 always a transition fit?
At these sizes it can produce either condition. Check the nominal size and limits; the result is not guaranteed for every band.
Why use H7/k6 instead of H7/js6?
The k6 zone sits higher than js6, so H7/k6 is shifted further toward interference and gives a firmer location. At 10, 25 and 50 mm the maximum clearance is still slightly larger than the maximum interference. H7/js6 is centred on nominal size.
Does H7/k6 transmit torque?
Not reliably by friction alone. Use a key, spline, clamp or other positive drive, and check the joint separately.
How is an H7/k6 joint assembled?
A light press or modest temperature difference may be needed. Base the method on the calculated interference and a check of contact pressure and material stress.
Does H7/k6 control roundness or surface finish?
No. It controls size only. Form, orientation and surface texture need separate specifications, and temperature and material affect the real fit.
References & calculation scope
The notation and fit framework follow ISO 286-1:2010; the tabulated tolerance classes and limit deviations are covered by ISO 286-2:2010. Every deviation on this page is generated from, and checked against, the same numerical engine as our calculator.
This independently written guide is not an ISO publication or certification. Examples cover dimensional size limits; they do not select a fit for a particular application.
YOUR SIZE. YOUR LIMITS.
Put a number to the fit.
Enter a basic size from 1 to 500 mm and compare the hole, shaft and clearance or interference limits.
Open the ISO 286 calculator