EngineeringFits中文 / Chinese version ↗

The engineering workbench / fits and machine elements

ISO 286 k6 Shaft Tolerance: Transition Fit with H7

Look up k6 shaft upper and lower deviations in micrometres, plus minimum and maximum sizes in millimetres. Values reuse the existing English ISO 286 dataset.

Table intervals cover nominal sizes greater than 0 and up to 500 mm. The existing English calculator supports 1–500 mm; results below 1 mm require verification.

02 / Read the limits

Results

Deviations in µm; nominal and limit sizes in mm.

CharacteristicResult · µm / mmInterpretation
Nominal size25 mmEnglish ISO 286 dataset.
Upper deviation+15 µmHole ES / shaft es.
Lower deviation+2 µmHole EI / shaft ei.
Minimum size25.002 mmNominal + lower deviation / 1000.
Maximum size25.015 mmNominal + upper deviation / 1000.

A missing table entry is displayed as “No tabulated value”; values are never interpolated. Individual drawing requirements take precedence over a general lookup.

k6 shaft size-range table

Nominal size > lower to ≤ upper · mmUpper deviation · µmLower deviation · µmVerification note
>0 to ≤3+60Below 1 mm NEEDS VERIFICATION
>3 to ≤6+9+1English dataset
>6 to ≤10+10+1English dataset
>10 to ≤14+12+1English dataset
>14 to ≤18+12+1English dataset
>18 to ≤24+15+2English dataset
>24 to ≤30+15+2English dataset
>30 to ≤40+18+2English dataset
>40 to ≤50+18+2English dataset
>50 to ≤65+21+2English dataset
>65 to ≤80+21+2English/Chinese mismatch; NEEDS VERIFICATION
>80 to ≤100+25+3English dataset
>100 to ≤120+25+3English dataset
>120 to ≤140+28+3English dataset
>140 to ≤160+28+3English dataset
>160 to ≤180+28+3English dataset
>180 to ≤200+33+4English dataset
>200 to ≤225+33+4English dataset
>225 to ≤250+33+4English dataset
>250 to ≤280+36+4English dataset
>280 to ≤315+36+4English dataset
>315 to ≤355+40+4English dataset
>355 to ≤400+40+4English dataset
>400 to ≤450+45+5English dataset
>450 to ≤500+45+5English dataset

03 / How to use

How to use this calculator

  1. This page looks up the ISO 286 k6 shaft class. Enter the nominal size of the shaft in the field below; the class is already fixed for this page.
  2. Read the upper and lower limit deviations and the resulting limits.
  3. The size-range table on this page lists the same deviations for every tabulated band.
  4. To evaluate the common pairing with an H7 hole, open the ISO 286 fit calculator and select H7 and k6 there. This page shows the k6 shaft limits only.
  5. Check both extremes before accepting the fit; a transition pair can produce either condition.

Table lookup, with explicit boundaries

Read the tabulated upper and lower deviations.
Minimum size = nominal + lower deviation / 1000.
Maximum size = nominal + upper deviation / 1000.
Deviations: µm; sizes: mm.

The first interval includes its lower tabulated size. Each following interval excludes its lower endpoint and includes its upper endpoint. The calculator rejects inputs outside the stated range and does not round inputs across a boundary.

04 / Engineering context

ISO 286 k6 Shaft Tolerance Class: Transition Fit with H7

A k6 shaft is a shaft tolerance class in ISO 286. The lowercase k places the shaft interval close to the nominal size, generally on the positive side, giving a small offset rather than the larger offset of a press-fit letter. The 6 is the IT6 grade. The exact position and width come from the standard's size tables; this page deliberately does not reproduce them.

H7/k6 is a familiar transition fit. The H7 hole starts at the nominal size, and the k6 shaft sits close to it, so the extreme cases can be a small clearance or a small interference. It is used for parts that need accurate location and some resistance to relative movement but must still be assembled or dismantled with light force. Gears, pulleys and hubs are common examples where the fit is expected to locate the part rather than carry major torque by friction alone.

A transition fit is not a guarantee of either condition. The actual result for a given assembly depends on where the hole and shaft fall inside their respective limits, and the design should state what happens at both extremes. If the application needs a guaranteed clearance, choose a clearance class; if it needs a guaranteed interference, choose an interference class. k6 also controls size only, so geometry and surface texture need separate requirements.

ISO 286 data source

Numerical source: existing ISO 286 JSON, with the h/H, js, f/g and k/p rules in the existing engine. Dataset edition label: ISO 286-1:2010 / ISO 286-2:2010. This lookup adds no new fundamental-deviation formula.

06 / Questions

Frequently asked questions

What does k6 mean?

The k is a shaft fundamental deviation placed close to the nominal size, generally on the positive side. The 6 is the IT6 tolerance grade and determines the zone width. Together they define the k6 shaft class.

What does H7/k6 mean?

H7/k6 is a hole-basis fit with an H7 hole and a k6 shaft. It is commonly used as a transition fit: the assembly may have a small clearance or a small interference depending on the actual sizes within the two tolerance zones.

Is H7/k6 always a transition fit?

It is commonly treated as one, but the actual result must be checked for the nominal size and the two limit deviations. Do not assume a particular clearance or interference from the class name alone; the calculator shows the range for the size you enter.

Why is k described as a transition deviation?

The k zone sits near the nominal size rather than far above it like a press-fit letter or clearly below it like a clearance letter. That position lets the hole and shaft zones overlap, so either a small clearance or a small interference is possible.

How does k6 differ from js6?

Both can form transition fits with H7, but their positions differ. js6 is centered on the nominal size, with deviations on both sides. k6 sits close to the nominal size on the positive side, so it is biased more toward interference than js6 is.

Can k6 be used for bearing shafts?

Some bearing arrangements use k6, but bearing manufacturers publish their own recommended shaft and housing fits for each bearing type, load direction and operating condition. Follow the bearing catalogue and application data rather than selecting k6 from the class name alone.

Does k6 guarantee torque transfer?

No. A transition fit may provide some friction, but it should not be assumed to carry a driven load. Use a key, spline, clamp or other positive drive where torque transfer is required, and check the joint design separately.

Does k6 control surface finish or roundness?

No. k6 controls the size of the shaft. Surface texture, roundness, cylindricity and alignment need separate specifications when they affect the fit or the function.