The engineering workbench / fits and machine elements
M5 × 0.8 Tap Drill: Core Hole for Metric Coarse Thread
Estimate a cutting-tap drill as nominal thread diameter D minus pitch P. Compare that estimate with provisional manufacturer chart drills for selected metric coarse and fine threads.
Selected candidate ISO 261/262 metric pitch series only. Pitch assignments, chart drill sizes and all minor-diameter limits NEEDS VERIFICATION. Forming taps are outside this calculator.
4.2 mm D − P estimate · *chart drill 4.2 mm, provisional, to be verified
02 / Read the limits
Results
Dimensions and deviations in mm. Verification notes apply to the displayed source.
| Characteristic | Result · mm | Interpretation |
|---|---|---|
| Thread D × P | 5 × 0.8 mm | coarse; pitch series NEEDS VERIFICATION against ISO 261/262. |
| Cutting-tap estimate D − P | 4.2 mm | Approximation; excludes forming taps. |
| Provisional chart drill | 4.2 mm | NEEDS VERIFICATION against ISO 2306 / DIN 336; manufacturer-specific. |
| Minor-diameter limits | NEEDS VERIFICATION | Not supplied; no tolerance class or limits inferred from D − P. |
A missing table entry is displayed as “No tabulated value”; values are never interpolated. Individual drawing requirements take precedence over a general lookup.
Selected coarse and fine pitch table — NEEDS VERIFICATION
| Thread | Series | Pitch · mm | D − P estimate · mm | Provisional chart drill · mm | Minor limits / status |
|---|---|---|---|---|---|
| M3 × 0.5 | coarse | 0.5 | 2.5 | 2.5 | Unavailable — NEEDS VERIFICATION |
| M4 × 0.7 | coarse | 0.7 | 3.3 | 3.3 | Unavailable — NEEDS VERIFICATION |
| M5 × 0.8 | coarse | 0.8 | 4.2 | 4.2 | Unavailable — NEEDS VERIFICATION |
| M6 × 1 | coarse | 1 | 5 | 5 | Unavailable — NEEDS VERIFICATION |
| M8 × 1.25 | coarse | 1.25 | 6.75 | 6.8 | Unavailable — NEEDS VERIFICATION |
| M10 × 1.25 | fine | 1.25 | 8.75 | 8.7 | Unavailable — NEEDS VERIFICATION |
| M10 × 1.5 | coarse | 1.5 | 8.5 | 8.5 | Unavailable — NEEDS VERIFICATION |
| M12 × 1.25 | fine | 1.25 | 10.75 | 10.8 | Unavailable — NEEDS VERIFICATION |
| M12 × 1.75 | coarse | 1.75 | 10.25 | 10.2 | Unavailable — NEEDS VERIFICATION |
| M16 × 1.5 | fine | 1.5 | 14.5 | 14.5 | Unavailable — NEEDS VERIFICATION |
| M16 × 2 | coarse | 2 | 14 | 14 | Unavailable — NEEDS VERIFICATION |
| M20 × 1.5 | fine | 1.5 | 18.5 | 18.5 | Unavailable — NEEDS VERIFICATION |
| M20 × 2.5 | coarse | 2.5 | 17.5 | 17.5 | Unavailable — NEEDS VERIFICATION |
| M24 × 2 | fine | 2 | 22 | 22 | Unavailable — NEEDS VERIFICATION |
| M24 × 3 | coarse | 3 | 21 | 21 | Unavailable — NEEDS VERIFICATION |
03 / How to use
How to use this calculator
- Confirm that the drawing specifies M5 × 0.8 and not another M5 pitch.
- Select the M5 × 0.8 — coarse preset in the calculator (it is preselected on this page), or enter D and P directly.
- The calculator has no tap-type or material input; it shows a D − P cutting-tap estimate and a provisional manufacturer chart drill (to be verified). A forming tap has its own hole requirement, so do not assume a cutting-tap result applies.
- Read the drill size from the result and record the assumptions that produced it.
- For a blind hole, plan drill depth for the tap chamfer and chips, and choose a tap style that can evacuate them.
- Check the finished thread with the specified gauge before accepting the part.
Table lookup, with explicit boundaries
Example: M8 × 1.25 → 8 − 1.25 = 6.75 mm (estimate).
The separate 6.8 mm manufacturer chart entry is provisional; it is not obtained by silently rounding every D − P result.
Minor-diameter limits are unavailable and are not derived from this formula.
Thread entries are selected discrete diameter/pitch pairs, not continuous standard ranges. Custom positive inputs with D > P are allowed for the formula only. A custom pair without chart data shows “Not tabulated”.
04 / Engineering context
M5 × 0.8 Tap Drill: Core Hole for a Metric Coarse Thread
M5 × 0.8 is the ISO metric coarse thread for M5 fasteners. It is common in light machinery, covers, brackets and fixtures, and it is often the point where manual tapping still feels comfortable but chip control starts to matter. Read the core-hole size from the calculator for M5 × 0.8 rather than assuming that every M5 thread uses the same drill.
The core hole affects both the torque needed to turn the tap and the amount of thread left in the part. In a blind hole, a hole that is too tight combines with poor chip evacuation and raises the chance of binding. A hole that is too open may tap easily but leave the joint short of the intended engagement. The right result depends on the tap chamfer, flute geometry, material and depth.
Aluminum, mild steel and stainless steel each respond differently: aluminum can gall, free-machining steel breaks chips readily, and some stainless grades work-harden. Lubrication and tap style therefore belong in the same decision as the drill size. Use the calculator result for M5 × 0.8, then check the tap manufacturer's recommendation for the material and coating.
Thread data sources and verification
Pitch and drill candidates were transcribed from the Tapmatic manufacturer chart; the M8 × 1.25 drill is from the Guhring SuperLine catalogue. Tapmatic’s chart assumes job drills cutting about 0.003 inch oversize. Manufacturer choices can differ.
NEEDS VERIFICATION: selected pitches against ISO 261 / ISO 262; recommended drills against ISO 2306 / DIN 336; minor-diameter limits against the specified thread tolerance standard and class. No minor-diameter limits are supplied.
06 / Questions
Frequently asked questions
What drill size should I use for M5 × 0.8?
Use the calculator on this page with the M5 × 0.8 selection, which shows a D − P cutting-tap estimate and a provisional chart drill (to be verified). The result is the core-hole size for those conditions, not a universal value for every M5 thread.
Is M5 × 0.8 a coarse thread?
Yes. M5 × 0.8 is the ISO metric coarse thread for the M5 nominal size. A different pitch would be a different thread and would need its own core-hole selection.
Should I use a cutting tap or a forming tap for M5 × 0.8?
The choice depends on the material, the hole type and the equipment. Cutting taps remove chips and suit a wide range of materials; forming taps displace material and can be productive in ductile grades when the hole is precise and lubrication is good. Do not mix a cutting-tap result with a forming tap; confirm the forming-tap hole with the tap maker.
Does aluminum need a different M5 × 0.8 core hole?
Aluminum can gall and tear, so lubrication and tap condition are important. The core hole may also need to follow the tap maker's recommendation for aluminum rather than a value chosen for steel. Confirm the combination on the actual alloy where possible.
How do I tap a blind M5 × 0.8 hole without packing chips?
Use a tap designed for blind holes, provide adequate depth below the thread, and clear chips when the operation permits. A bottoming tap reduces the chamfer length but still needs clearance at the bottom of the hole.
How much thread engagement does an M5 × 0.8 joint need?
The required engagement comes from the joint design, the material and the loads, not from the drill size alone. The core hole should support that requirement within the tap maker's range. If the available engagement is marginal, change the boss or fastener design rather than forcing a tight hole.
Can I check the M5 × 0.8 thread with the mating screw?
A known-good mating screw is a useful shop check, but it does not replace the specified thread gauge for acceptance. Use the drawing's inspection requirement and check the core hole separately if the process depends on it.